Turn the sensitive switch to stir to the
??NOM?? position
??
Turn the setting switch to stir to the
??SET?? position enter programming mode, LED display ??00??
??
Keep press the coin adjust switch more
than 5 seconds until you will be hear a ??BI?? sound and LED will display ??C??,
this moment is all the coin value setting is erased
??
Turn the setting switch to stir to the
??START?? position exit programming mode
This is only for advance user.
??
Turn the sensitive switch to stir to the
??NOM?? position
??
Turn the setting switch to stir to the
??SET?? position enter programming mode, LED display ??00??
??
Press the coin adjust switch to adjust
the coin value in turn and let the LED display the value, which you want to
erase.
??
Keep press the coin adjust switch for
more than 5 seconds until you will be hear a ??BI?? sound and LED will display
??C??, this moment is this coin group value setting is erased
??
Turn the setting switch to stir to the
??START?? position exit programming mode
??
Turn the sensitive switch to stir to the ??MGN??
position
??
Turn the setting switch to stir to the
??SET?? position to enter programming mode, LED display ??P2??
??
Keep press the coin adjust switch for 10
seconds until you will be hear a ??BI?? sound and LED will display ??C??, this
moment is the coin value setting is erased
??
Turn the sensitive switch to stir to the
??NOM?? position
??
Turn the setting switch to stir to the
??START?? position to exit programming mode
??
Turn the sensitive switch to the ??NOM??
position
??
Turn the Setting
Switch to the ??SET?? position enter programming
mode, LED display ??00??
??
Press the Adjust
Setting Switch to adjust the coin value in turn
and let the LED display the value, which you needed, for example ??01?? or ??02??.
The value increase 1 upon 1 press. If you passed the value you want to set, just
turn the setting switch to stir to ??START?? then turn back to ??SET?? again
the LED will display ??00??, so you can select the value again.
??
Deposit the coins in turn, you can program up
to 10 coins .If less than 10 coins can add and store later. For example you can
prepare 10 quarters as different condition as possible. Or you can deposit 10
same or different tokens.
??
Repeat above two steps to set other coin group
values.
??
Turn the setting switch to stir to the
??START?? position to exit programming mode
1.5
Example A : Setup for Canadian
Quarter(0.25), Loony($1.00), Toony ($2.00)
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 10 Canadian Quarters, 10 Loonies, 10 Toonies.
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch once, the display will show ??01??, drop
the 10 quarters in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.( if you accident press more
times, for example the display show ??01?? or ??02??, then turn the Setting
Switch to START, then turn Setting Switch to SET again
the display will show ??00??. So you can do the this step)
6.
Press Adjust Setting Switch3 times until the display show ??04??,
drop the 10 Loonies in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.
7.
Press Adjust Setting Switch 4 times until the display show ??08??,
drop the 10 Toonies in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.
8.
Turn Setting Switch to START, then your AC5 is ready to
use.
9.
When you drop 1 quarter, it will output one pulse signal, drop 1 Loony it
will output 4 pulse signal, drop 1 Toony it will output 8 pulse signal
1.6
Example B : Setup for Canadian
Nickel(0.05), Dime (0.10), Quarter(0.25), Loony($1.00), Toony ($2.00) output
pulse only up to 0.25.
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10
Toonies.
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch once, the display will show ??01??, drop
the 10 nickels in sequence, when you drop the 10th nickel, the
display will show ??F?? means the setting is done.( if you accident press more
times, for example the display show ??01?? or ??02??, then turn the Setting
Switch to START, then turn Setting Switch to SET again
the display will show ??00??. So you can do the this step)
6.
press Adjust Setting Switch once, the display will show ??02??, drop
the 10 dimes in sequence, when you drop the 10th dime, the display
will show ??F?? means the setting is done
7.
press Adjust Setting Switch 3 time, the display will show ??05??,
drop the 10 quarters in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done
8.
Press Adjust Setting Switch 15 times until the display show ??20??,
drop the 10 Loonies in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.
9.
Press Adjust Setting Switch 20 times until the display show ??40??,
drop the 10 Toonies in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.
10.
Turn the sensitive switch
to MGN
11.
Press Adjust Setting Switch 5 times until the display show ??05??
12.
Turn Setting Switch to START, then your AC5 is ready to
use.
10.
When you drop 1 quarter, it will output one pulse signal, drop 1 Loony it
will output 4 pulse signal, drop 1 Toony it will output 8 pulse signal, and only
when you drop 5 nickels = 1 dime and 3 nickels = 2 dimes and 1 nickles >= 0.25
then it will output 1 pulse signal.
1.7
Example C: Setup for US quarter output 8
pulse signal
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10
Toonies.
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch 8 time, the display will show ??08??,
drop the 10 quarters in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done
6.
Press Adjust Setting Switch 15 times until the display show ??20??,
drop the 10 Loonies in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done.
7.
Turn Setting Switch to START, then your AC5 is ready to
use.
8.
When you drop 1 quarter, it will output one pulse signal, drop 1 quarter
it will output 8 pulse signals
1.8
Example D : Setup for US$ Nickel(0.05),
Dime (0.10), Quarter(0.25), output 1 pulse only up to 0.25.
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10
Toonies.
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch once, the display will show ??01??, drop
the 10 nickels in sequence, when you drop the 10th nickel, the
display will show ??F?? means the setting is done.( if you accident press more
times, for example the display show ??01?? or ??02??, then turn the Setting
Switch to START, then turn Setting Switch to SET again
the display will show ??00??. So you can do the this step)
6.
press Adjust Setting Switch once, the display will show ??02??, drop
the 10 dimes in sequence, when you drop the 10th dime, the display
will show ??F?? means the setting is done
7.
press Adjust Setting Switch 3 time, the display will show ??05??,
drop the 10 quarters in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done
8.
Turn the sensitive switch
to MGN
9.
Press Adjust Setting Switch 5 times until the display show ??05??
10.
Turn Setting Switch to START, then your AC5 is ready to
use.
11.
When you drop 1 quarter, it will output one pulse signal, and only when
you drop 5 nickels = 1 dime and 3 nickels = 2 dimes and 1 nickels >= 0.25 then
it will output 1 pulse signal.
1.9
Example E : Setup for drop 4 Quarter(0.25), output 1 pulse
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 10 Quarters
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch 1 time, the display will show ??01??,
drop the 10 quarters in sequence, when you drop the 10th quarter, the
display will show ??F?? means the setting is done
6.
Turn the sensitive switch
to MGN
7.
Press Adjust Setting Switch 4 times until the display show ??04??
8.
Turn Setting Switch to START, then your AC5 is ready to
use.
9.
Only when you drop 4 quarter, it will output one pulse signal,
1.1
Example F : Setup for drop US
Quarter(0.25), Canadian Quarter, Canadian Loonie, Canadian Toonie, all output 1
pulse signal
1.
Clear all the settings. Do the 4.1 and 4.3 to erase
previous settings.
2.
Prepare 3 US Quarters, 3 Canadian Quarters, 2 Canadian Loonies, 2
Canadian Toonies
3.
Turn the sensitive switch
to NOM
4.
Turn the Setting Switch to SET going to Programming mode,
the display will show ??00??
5.
press Adjust Setting Switch 1 time, the display will show ??01??,
drop the all above coins in sequence, when you drop the 10th coin,
the display will show ??F?? means the setting is done
6.
Turn Setting Switch to START, then your AC5 is ready to
use.
7.
Only when you drop one of any above coins, it will output one pulse
signal,
|