Convert anything or everything into coin operated, bill operated, card operated.


1.5 Example A : Setup for Canadian Quarter(0.25), Loony($1.00), Toony ($2.00)
 
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 10 Canadian Quarters, 10 Loonies, 10 Toonies.
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch once, the display will show 01, drop the 10 quarters in sequence, when you drop the 10th quarter, the display will show F means the setting is done.( if you accident press more times, for example the display show 01 or 02, then turn the Setting Switch to START, then turn Setting Switch to SET again the display will show 00. So you can do the this step)
6. Press Adjust Setting Switch3 times until the display show 04, drop the 10 Loonies in sequence, when you drop the 10th quarter, the display will show F means the setting is done.
7. Press Adjust Setting Switch 4 times until the display show 08, drop the 10 Toonies in sequence, when you drop the 10th quarter, the display will show F means the setting is done.
8. Turn Setting Switch to START, then your AC5 is ready to use.
9. When you drop 1 quarter, it will output one pulse signal, drop 1 Loony it will output 4 pulse signal, drop 1 Toony it will output 8 pulse signal
1.6 Example B : Setup for Canadian Nickel(0.05),  Dime (0.10), Quarter(0.25), Loony($1.00), Toony ($2.00) output pulse only up to 0.25.
 
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10 Toonies.
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch once, the display will show 01, drop the 10 nickels in sequence, when you drop the 10th nickel, the display will show F means the setting is done.( if you accident press more times, for example the display show 01 or 02, then turn the Setting Switch to START, then turn Setting Switch to SET again the display will show 00. So you can do the this step)
6. press Adjust Setting Switch once, the display will show 02, drop the 10 dimes in sequence, when you drop the 10th dime, the display will show F means the setting is done
7. press Adjust Setting Switch 3 time, the display will show 05, drop the 10 quarters in sequence, when you drop the 10th quarter, the display will show F means the setting is done
8. Press Adjust Setting Switch 15 times until the display show 20, drop the 10 Loonies in sequence, when you drop the 10th quarter, the display will show F means the setting is done.
9. Press Adjust Setting Switch 20 times until the display show 40, drop the 10 Toonies in sequence, when you drop the 10th quarter, the display will show F means the setting is done.
10. Turn the sensitive switch to MGN
11. Press Adjust Setting Switch 5 times until the display show 05
12. Turn Setting Switch to START, then your AC5 is ready to use.
10. When you drop 1 quarter, it will output one pulse signal, drop 1 Loony it will output 4 pulse signal, drop 1 Toony it will output 8 pulse signal, and only when you drop 5 nickels = 1 dime and 3 nickels = 2 dimes and 1 nickles >= 0.25 then it will output 1 pulse signal.
1.7 Example C: Setup for US quarter output 8 pulse signal
 
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10 Toonies.
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch 8 time, the display will show 08, drop the 10 quarters in sequence, when you drop the 10th quarter, the display will show F means the setting is done
6. Press Adjust Setting Switch 15 times until the display show 20, drop the 10 Loonies in sequence, when you drop the 10th quarter, the display will show F means the setting is done.
7. Turn Setting Switch to START, then your AC5 is ready to use.
8. When you drop 1 quarter, it will output one pulse signal, drop 1 quarter it will output 8 pulse signals
1.8 Example D : Setup for US$ Nickel(0.05),  Dime (0.10), Quarter(0.25), output 1 pulse only up to 0.25.
 
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 10 Nickels, 10 Dimes, 10 Canadian Quarters, 10 Loonies, 10 Toonies.
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch once, the display will show 01, drop the 10 nickels in sequence, when you drop the 10th nickel, the display will show F means the setting is done.( if you accident press more times, for example the display show 01 or 02, then turn the Setting Switch to START, then turn Setting Switch to SET again the display will show 00. So you can do the this step)
6. press Adjust Setting Switch once, the display will show 02, drop the 10 dimes in sequence, when you drop the 10th dime, the display will show F means the setting is done
7. press Adjust Setting Switch 3 time, the display will show 05, drop the 10 quarters in sequence, when you drop the 10th quarter, the display will show F means the setting is done
8. Turn the sensitive switch to MGN
9. Press Adjust Setting Switch 5 times until the display show 05
10. Turn Setting Switch to START, then your AC5 is ready to use.
11. When you drop 1 quarter, it will output one pulse signal, and only when you drop 5 nickels = 1 dime and 3 nickels = 2 dimes and 1 nickels >= 0.25 then it will output 1 pulse signal.
1.9 Example E : Setup for drop 4 Quarter(0.25), output 1 pulse
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 10 Quarters
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch 1 time, the display will show 01, drop the 10 quarters in sequence, when you drop the 10th quarter, the display will show F means the setting is done
6. Turn the sensitive switch to MGN
7. Press Adjust Setting Switch 4 times until the display show 04
8. Turn Setting Switch to START, then your AC5 is ready to use.
9. Only when you drop 4 quarter, it will output one pulse signal,
1.1 Example F : Setup for drop US Quarter(0.25), Canadian Quarter, Canadian Loonie, Canadian Toonie, all output 1 pulse signal
1. Clear all the settings. Do the 4.1 and 4.3 to erase previous settings.
2. Prepare 3 US Quarters, 3 Canadian Quarters, 2 Canadian Loonies, 2 Canadian Toonies
3. Turn the sensitive switch to NOM
4. Turn the Setting Switch to SET going to Programming mode, the display will show 00
5. press Adjust Setting Switch 1 time, the display will show 01, drop the all above coins  in sequence, when you drop the 10th coin, the display will show F means the setting is done
6. Turn Setting Switch to START, then your AC5 is ready to use.
7. Only when you drop one of any above coins, it will output one pulse signal,